REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Thursday, 28 February 2019

SCHEUTEN MODULES SOLEXUS - SOLAR-PANEL JUNCTION-BOX REPAIR

Scheuten Modules Solexus - Solar-panel Junction-Box repair

Repair of the Solexus junction-box of ScheutenSolar solar panels with the Scheuten Modules repair-kit of New Energy Systems Services. This repair is necessary because of the fire danger of the original junction-box. The repair may only be performed by professional solar installers, who strictly have to carry out this manual. Improper, incorrect or incomplete repair of the junction box can lead to dangerous situations. New Energy Systems Services cannot be held responsible for incorrect repair of junction-boxes. The repair can be performed in the field, whereby the local (safety) regulations (e.g. for working at heights) should be taken into account. The repair should be carried out during dry weather circumstances (no condensing) and the temperature should be above 5˚ Celsius. All activities at the junction-box itself should be carried out with clean hands.
ScheutenSolar used two kinds of PCB’s in the Solexus junction-box. This depends on the type of solar panel. Make sure you use the right repair-kit before you start with the repair; this is indicated on the packaging of the repair-kit. The 8-pole connector on the PCB also indicates for which type of solar panel the PCB is suitable.
1) Repair-kit for standard Multisol-modules (8-pole pin length 17,0 till 17,5mm).
2) Repair-kit for Vitro/Integra-modules (8-pole pin length 19,0 till 19,5mm)
Make sure the pin length of the 8-pole of the removed PCB is identical to the pin length of the 8- pole of the repair-kit. Replacing the old PCB by a PCB with a different pin length is not allowed.
1 PCB with red (+) and blue (-) connection wire.
2 (-) connector (chassis part), Multi-Contact order.nr. 32.0077P001 with adapter ring M12/M16.
3 Screw fit with PRELOK, type Scotchgrip 2353.
4 (+) connector (chassis part), Multi-Contact order.nr. 32.0076P001 with adapter ring M12/M16.
To carry-out the repair, you need (besides standard tools) the following special tools.
5 Torque (crosshead PH1) screwdriver, e.g. Facom A.300 MT (4-20 cNm).
6 Multi-Contact Wrench, Multi-Contact order number 32.6026.
7 Multi-Contact Test-plug, Multi-Contact order number 32.6028.
8 Special curved screwdriver (flat head) 4.0x100mm, angle 35˚ on 35mm from tip.
Shut-down the AC- and DC-voltage of your PV-system. Remove the solar panel from the sub structure.
The cover of the Solexus junction-box can be clicked off at the 4 corners with a flat head screwdriver.
After removing the cover, you can see the PCB from the solder side. The 2 U-shaped mechanical interlocks that lock the cable to the housing (photo 4), must be removed by clicking them out with a screwdriver.
Remove the screw that locks the circuit board.
Warning: do NOT re-use the screw.
Cut the cables behind the swivels (photo 6) and remove the swivels with a wrench.
Now the old PCB can be removed carefully by pressing the 4 latches on the outside of the junction box. What remains is an empty junction box with the 8-pole female connector visible in the back of the
module.
The dismantling of the old components is ready. Now, you can start installing the new components.
First, the 2 Multi-Contact MC4 chassis parts (2 and 4) of the repair-kit can be installed. Each chassis part is provided with a M12/M16 adapter ring. The (-) connector (2) should be installed on the left, the (+) connector (4) on the right. The chassis parts must be tightened with the Multi-Contact Wrench (6) and a socket wrench (15mm with torque-control) with a torque of 2,0 Nm.
Install the new, modified PCB (1) of the repair-kit. Make sure that the 4 interlocks on the outside click ‘over’ the PCB. Press the 8-pole connector firmly, to make sure that it makes contact with the female connector in the module with no spacing between.
Secure the PCB with the screw (3) of the repair-kit (photo 10). The srew is already provided with PRELOK (thread locker) to lock the connection (after tightening). The screw must be tightened with a suitable tool (5) with 0,15Nm.
The PCB is now mechanical locked and the chassis parts are in position. Next, the MC4-inserts must be clicked into the chassis parts. This is the most difficult action of the whole repair and should be done very precisely. Before the inserts are clicked into the chassis parts, the wires should be turned into a loop whereby the loop is pointing towards the outside of the junction-box. After that, press through the inserts.
Press through the inserts in the chassis parts using the curved (flat head) screwdriver (8), until it locks. This requires some practice where to pay attention that no parts get damaged (the insert itself, but also the wire, PCB, housing etc.)
Make sure the insert is locked well into the chassis part by carefully pulling the wire. Also check the position of the insert from the outside with the test plug (7), on the by Multi-Contact prescribed way. After a last visual check, the cover can be clicked on the junction-box again.