PANASONIC TX - W32D4DP SERVICE MODE ADJUSTMENTS
TO ENTER SERVICE MODE [FACTORY MODE]
- To return customer settings ot Factory settings and clear owner ID of all information input by the user, enter Self Check Mode.
- Press Down ( -/V ) button on the customer control at the front of the TV set, at the same time pressing the "STATUS" button [ +] on the remote control.
- To "Exit" Self Check, switch OFF the TV set at the Power Button.
- Self check should only be used when refurbishing the TV set, and not during normal repair work.
Self check is also used to automatically check the Bus Lines,
and Hexadecimal code of the tV set. If CCU ports have been checked and
found to be incorrect or not located, then "---" will appear in place of
"OK"
SELF CHECK SCREEN
VPC
|
OK
|
||
TUN
|
OK
|
PCB
|
OK
|
E2
|
OK
|
||
DPL
|
OK
|
CAB
|
OK
|
CIP 1
|
OK
|
||
CIP 2
|
OK
|
SUM
|
Factory use only
|
VP
|
OK
|
||
DFU
|
OK
|
||
COL
|
OK
|
||
PIP
|
OK
|
||
OPTION 1
|
B9
|
||
OPTION 2
|
FD
|
||
OPTION 3
|
1F
|
||
OPTION 4
|
0D
|
||
OPTION 5
|
FB
|
||
OPTION 6
|
63
|
ALIGNMENT SETTINGS
- Set the 'Bass' to maximum position, set treble to minimum position. Press the Down Button ( - / V ) on the customer controls at the front of the TV and at the same time press the "INDEX' button on the remote control, this will place the TV into the Service Mode.
- Press the 'Red'/'Green' buttons to step up / down through the functions.
- Press 'Yellow' / 'Blue' buttons to alter the function values.
- Press "STR" button after each adjustment has been made to store the required values in memory.
- To "EXIT" service mode, press the "N" button.
Alignment function
|
Settings / Special features
|
|
Horizontal position
|
H-pos [+020]
|
Optimum settings
|
Vertical position
|
V-pos [+024]
|
Optimum setting
|
Horizontal amplitude
|
H – amp [+049]
|
Optimum setting
|
Vertical amplitude
|
V –amp [+029]
|
Optimum setting
|
EW-Amplitude
|
E/W Amp-1 [+022]
|
Optimum setting
|
EW- amplitude
|
E/W Amp-2 [000]
|
Optimum setting
|
Trapezium-comp
|
Trapez-1 [+033]
|
Optimum setting
|
Horizontal - parallel
|
H-Parallel [+032]
|
Optimum setting
|
Vertical linearity
|
V-Lin [+044]
|
Optimum setting
|
DVCO
|
DVCO [0000]
|
Receive a PAL color bar pattern. For DVCO alignment press “Blue” button, wait until colors are
stable and press ‘STR’.
|
Cut-off DC
|
Cut-off [OK]
|
To adjust cut-off adjust the screen VR until the display
shows “OK”.
|
Highlight
|
High – 0031
0031 0031
|
Contrast
Maximum
A.I
Off
Optimum setting.
|
Sub brightness
|
Sub-brightness [0000]
|
Optimum setting.
|