SHARP LC-32DH510E643 - LCD TV - W/B ADJUSTMENT - INITIALIZATION - LAMP ERROR DETECTION
WHITE BALANCE ADJUSTMENT- Condition: AV MODE= Dynamic(backlight at max.).
- Adjustments reference device: Minolta CA-210
- Adjustments target: x=0.272, y=0.277
- High: adjustments spec ±0.001, inspection spec: ±0.002
- Low: adjustments spec ±0.002, inspection spec: ±0.004
To adjsut W/B, you have to enter its
Service Mode option. To get details about how to enter service mode to
this set, refer previous post here.
- Press “▼” until selecting “GAMMA” option.
- Press “OK”.
- “GAMMA” menu appears.
- Press “▼” until selecting “MGAMMA RESET”.
- Press “►”, to restore default values.
- “MGAMMA RESET SUCCESS” appears.
- Press “P+” to increase one page.
- Press “1”, appears “Internal Adjustments Pattern 1”.
- Hold the default value for “MGAMMA G1”. (Note: next, try to get the (x, y) adjustments target,changing “MGAMMA R1” and “MGAMMA B1” as follow).
- Press “▼” until selecting “MGAMMA R1”.
- Press “◄ ►” until you obtain the desired value.
- Press “MENU” to return to previous menu.
- Press “▼” until selecting “MGAMMA B1”.
- Press “◄ ►” until you obtain the desired value.
- Press “MENU” to return to previous menu. (Note: In case of not being possible to achieve the desired (x, y) target, try to get it by changing also the “MGAMMA G1”)
- Press “2”, appears “Internal Adjustments Pattern 2”.
- Repeat from step 9 to 15 for the “MGAMMA R2” and “MGAMMA B2”.
- Press “3”, appears “Internal Adjustments Pattern 3”.
- Repeat from step 9 to 15 for the “MGAMMA R3” and “MGAMMA B3”.
- Press “4”, appears “Internal Adjustments Pattern 4”.
- Repeat from step 9 to 15 for the “MGAMMA R4” and “MGAMMA B4”.
- Press “5”, appears “Internal Adjustments Pattern 5”.
- Repeat from step 9 to 15 for the “MGAMMA R5” and “MGAMMA B5”.
- Press “6”, appears “Internal Adjustments Pattern 6”.
- Repeat from step 9 to 15 for the “MGAMMA R6” and “MGAMMA B6”.
- Press “▼” until selecting “MGAMMA WRITE”.
- Press “►”, to save the new values.
- “MGAMMA WRITE SUCCESS” appears
INITIALIZATION TO FACTORY SETTING
Caution: When the factory settings have been made, all user
setting data, including the channel settings, are initialized. (The adjustments done in the adjustment
process mode are not initialized.) Keep this in mind when initializing these
settings.
- Enter in Service mode.
- Press “▼” or “▲” key until selecting INIT.
- Press OK key.
- INIT menu appears and “Factory init” option is selected.
- Press “◄” or “►” until selecting the option desired (EURO/RUSSIA/SWEDEN/UK/EAST EUROPE).
- Press OK key and initialization starts.
OK, RUSSIA message appears for RUSSIA option when the
setting is complete.
OK, SWEDEN message appears for SWEDEN option when the
setting is complete.
OK, UK message appears for UK option when the setting is
complete.
OK, EAST EUROPE message appears for EAST EUROPE option when
the setting is complete.
Note: Never turn the power off during initialization.- To exit the adjustment process mode, unplug the AC power cord from the outlet to forcibly turn off the power.
- User settings
- Channel data (e.g. broadcast frequencies)
- Maker option setting
- Password data.
LAMP ERROR DETECTION
This LCD color television has a function (lamp error
detection) to be turned OFF the TV set automatically for safety criteria when
the lamp or lamp circuit is abnormal.
If the lamp or lamp circuit is abnormal, or some other
errors happen, and the lamp error detection is executed, the following occurs:
- The TV set is turned OFF automatically 20 seconds after it is turned ON by the user. (The power LED on the front side of TV turns from green to red)
- If the situation “stated above.” happens 5 times sequentially, it becomes impossible to turn on the power. (The power LED turns from green to red and keeps blinking in red).
COUNTERMEASURES
- Checking with [L Error Check Off]. Repair the problem that produces the LAMP ERROR. The TV remains with power LED blinking until K mode is forced by local keyboard, in order to disable the LAMP ERROR detection. To disable the LAMP ERROR feature is necessary enter in K mode by pressing “VOL DOWN” and “à[ ]” keys at same time when the AC cord is plugged in.
- Resetting the LAMP ERROR counter. After the lamp and lamp circuit are found out of trouble, the LAMP ERROR counter should be reset. If a LAMP ERROR is detected five consecutive times, the power cannot be turned on.
Method 1: Using the cursor (UP/DOWN) key, move to the cursor
to [L Error Reset] on Line 6 of ETC Menu. With the cursor (LEFT/RIGHT) keys
reset the value to “0”.
Method 2: In the case the TV is not blocked (less than
5 consecutive errors), switch on the Set. After 30 minutes working, the LAMP