REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Monday 1 April 2019

PHILIPS 42PFL5604-77 - SERVICE MODE – ERROR CODES [LED BLINKING CODES] DETAILS

APPLICABLE TO _ PHILIPS 32PFL5604-78__ PHILIPS 32PFL5604-77__ PHILIPS 42PFL5604-77 - SERVICE MODE – ERROR CODES [LED Blinking codes] Details.
SERVICE MODES
Note: For the new model range, a new remote control (RC) is used with some renamed buttons. This has an impact on the activation of the Service modes. For instance the old “MENU” button is now called “HOME” (or is indicated by a “house” icon).  Service Default mode (SDM) and Service Alignment Mode (SAM) offer several features for the service technician, while the Customer Service Mode (CSM) is used for communication between the call centre and the customer.  This chassis also offers the option of using ComPair, a hardware interface between a computer and the TV chassis. It offers the abilities of structured troubleshooting, error code reading, and software version read-out for all chassis.
SDM [Service Default Mode]
To start the blinking LED procedure where only layer 2 errors are displayed.
TO ACTIVATE THE SDM
Use the standard RC-transmitter and key in the code “0 6 2 5 9 6”, directly followed by the “MENU/HOME” button. After activating this mode, “SDM” will appear in the upper right corner of the screen (when a picture is available).
TO NAVIGATE THROUGH SDM
When the “MENU” (or HOME) button is pressed on the RC transmitter, the set will toggle between the SDM and the normal user menu (with the SDM mode still active in the background).
TO EXIT THE SDM
Switch the set to STAND-BY via the RC-transmitter.
SAM [Service Alignment Mode]
1.To perform (software) alignments.
2. To change option settings.
3. To easily identify the used software version.
4. To view operation hours.
5. To display (or clear) the error code buffer.
To activate SAM
Via a standard RC transmitter: key in the code “0 6 2 5 9 6” directly followed by the “ i/I NFO” button.
Contents of SAM
Syst. Info. Giving overview of: – Op. Hours. During the life time cycle of the TV, a life time is kept. It counts the normal operation hours, not the Stand-by hours. The actual value of the life timer is displayed in SAM in decimal value. For every two startups the counter increases by one. Min. 5 digits are displayed in decimal digits. In detail:
* Every 2x cold start-ups, to display a picture, increases the counter by 1 (i.e. interrupt the mains supply 2x while the set is ON).
* Every 2x warm start-ups (from Stand-by), to display a picture, increases the counter by 1.
* Every hour of normal operating increases the counter by 1 (i.e. if a set is continue ON for 2 hours, then increase the counter by 2).
* Stand-by hours are NOT counted.
Main SW ID. > Displays the loaded main SW version.
Error Clear Codes. 
When “arrow right” is pressed and then the “OK” button is pressed, the error buffer is reset.
* Options. Choosing the CTN will set the options, see also
* RGB Align. This will activate the alignments sub-menu.
* NVM Editor. This will give the opportunity to directly change values in the NVM by selecting the address and value. Use decimal values.
NVM Copy. For easy transfer of NVM settings:
> Copy to USB. To upload several settings from the TV to an USB stick. See 5-1 USB Copy content. To upload the settings, press “arrow right” (or the “OK button), confirm with “OK” and wait until “OK” appears. Now the settings are stored onto the USB stick can be used to download to another TV or other SSB. Uploading is of course only possible if the software is running and if a picture is available. This method is created to be able to save the customer’s TV settings and to store them into another SSB.
Copy from USB. To download several settings from the USB stick to the TV. Same way of working as with uploading. To make sure that the download of the channel list from USB to the TV is execute properly, it is necessary to restart the TV and tune to a valid preset if necessary.
USB Copy content
> Tuner. This will activate the alignments sub-menu.
Tuner AGC (RF AGC Take Over Point Adjustment)
> Auto ADC. This will activate the alignments sub-menu.
TO NAVIGATE
* In SAM, the menu items can be selected with the “Arrow up/down” ( ▲/▼)key on the RC-transmitter. The selected item will be highlighted. When not all menu items fit on the screen, move the “Arrow up/down” key to display the next/previous menu items. * With the “Arrow Left/Right” (◄/►)keys, it is possible to: > (De) activate the selected menu item.
> (De) activate the selected sub menu.
* With the “OK” key, it is possible to activate the selected action.
* With the “Menu/Home” key, it is possible to go back to the previous selection.
TO EXIT THE SAM
Switch the set to STAND-BY via the RC-transmitter.
ERROR CODES
  The error code buffer contains all detected errors since the last time the buffer was erased. The buffer is written from top to bottom (or left to right), new errors are logged at the top/left side, and all other errors shift one position to the bottom/right.  When an error occurs, it is added to the list of errors, provided the list is not full. When the error buffer is full, then the new error is not added, and the error buffer stays intact (history is maintained).  To prevent that an occasional error stays in the list forever, the error is removed from the list after more than 50 hrs. of operation.
There is a simple blinking LED procedure for board level repair (home repair) the so called LAYER 1 errors, next to the existing errors which are LAYER 2 errors:
* LAYER 1 errors are one digit errors
* LAYER 2 errors are two digit errors.
When is LAYER 1 or 2 available
* In CSM mode: When entering CSM: error LAYER 1 will be displayed by blinking LED. Only the latest error is shown.
* In SDM mode: When SDM is entered via Remote Control code, LAYER 2 is displayed via blinking LED.
ON-SCREEN ERROR DISPLAY
* In CSM, no error codes are displayed on screen.
* In SAM, the complete error list is shown.
  If possible, check the entire contents of the error buffer. In some situations, an error code is only the result of another error code and not the actual cause (e.g. a fault in the protection detection circuitry can also lead to a protection).  In case of non-intermittent faults, clear the error buffer before starting to repair (before clearing the buffer, write down the content, as this history can give significant information). This is to ensure that old error codes are no longer present.
TO READ ERROR BUFFER
Use one of the following methods
* On screen via SAM (only when apicture is visible). E.g.:
> 000 000 000 000 000: No errors detected
> 017 000 000 000 000: Error code 17 is the last and only detected error.
> 015 017 000 000 000: Error code 17 was first detected and error code 15 is the last detected error.
*  Via the Blinking LED procedure.
*  Via ComPair.
TO CLEAR ERROR BUFFER
Use one of the following methods:
* By activation of the “Clear Codes” command in the SAM menu.
* With a normal RC, key in sequence “062599” followed by “OK”
Take notice that some errors need several minutes before they start blinking or before they will be logged. So in case of problems wait 2 minutes from start-up onwards, and then check if the front LED is blinking or if an error is logged.
LAYER-1 & LAYER-2 CODE Overview
LED BLINKING PROCEDURE {Layer-2 codes]
The software is capable of identifying different kinds of errors.  Because it is possible that more than one error can occur over time, an error buffer is available that is capable of storing the last five errors that occurred. This is useful if the OSD is not working properly.  Errors can also be displayed by the blinking LED procedure.  The method is to repeatedly let the LED pulse with as many pulses as the error code number, followed by a time period of 1.5 seconds in which the LED is “off”. Then this sequence is repeated.
E.g. error code 4 will result in four times the sequence LED “on” for 0.25 seconds / LED “off” for 0.25 seconds. After this sequence the LED will be “off” for 1.5 seconds. Any RC command terminates this sequence.
Displaying the entire error buffer
The entire error buffer can be displayed when service mode “SDM” is entered (by remote control command 062596 >MENU). When in protection, this sequence will not work, but than LAYER-1 error code should suffice.  In order to avoid confusion with RC signal reception blinking, this blinking procedure is terminated when a RC command is received.
How to Activate
Use one of the following methods:
1. Activate the CSM. The blinking front LED will show only the latest LAYER-1 error.
2. Activate the SDM. The blinking front LED will show the entire contents of the LAYER-2 error buffer.
The procedures given above are common to 90% of LCD TVs; made by PHILIPS; irrespective to its screen size.