REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Wednesday 11 December 2019

SAMSUNG LCD TVS LE32A43*T**, LE37A43*T**, LE40A43*T** HOW TO DISASSEMBLE, HOW TO TROUBLESHOOT


Samsung Chassis: GTN32SE*, GTN37SE*, GTN40SE* LE37A43** series LCD TVs - Service mode, fault finding, alignments, disassembly, white balance adjustment, color alignments
Disassembly
Place monitor face down on cushioned table.
Remove the screws from the Stand.
Remove stand.
Lift up rear cover and remove the stand.
Remove Screw from the stand BRKT and lift up the stand BRKT
Disconnect cable from the boards.
Remove the screws of Main Board and SMPS
Remove screws and lift up the BRKT from the front cover. And then take the panel off.
Reassembly procedures are in the reverse order of disassembly procedures.
Troubleshooting No Power
The LEDs on the front panel do not work when connecting the power cord.
The SMPS relay does not work when connecting the power cord.
The units appears to be dead
 Major checkpoints
The IP relay or the LEDs on the front panel does not work when connecting the power cord if the cables are
improperly connected or the Main Board or SMPS is not functioning. In this case, check the following:
Check the internal cable connection status inside the unit.
Check the fuses of each part.
Check the output voltage of SMPS.
Replace the Main Board.
No Video (Analog PC signal)
Audio is normal but no picture is displayed on the screen
Check the PC source
Check the SEMS01
This may happen when the LVDS cable connecting the Main Board and the Panel is disconnected.
No Video (HDMI - Digital Signal)
Audio is normal but no picture is displayed on the screen
Check the HDMI source
Check the SEMS01
This may happen when the LVDS cable connecting the Main Board and the Panel is disconnected.
No Video (Tuner_CVBS)
Audio is normal but no picture is displayed on the screen
Check the Tuner CVBS source
Check the SEMS01
This may happen when the LVDS cable connecting the Main Board and the Panel is disconnected.
No Picture (S-VIDEO_Y,C)
Audio is normal but no picture is displayed on the screen
Check the S-Video_Y,C source
Check the SEMS01
This may happen when the LVDS cable connecting the Main Board and the Panel is disconnected.
Audio circuit is normal but no sound output
Check the RF Source
Check the SEMS01
This may happen when the LVDS cable connecting the Main Board and the Panel is disconnected.
Wiring details
Alignments and Adjustments
Usually, a color LCD-TV needs only slight touch-up adjustment upon installation.
Check the basic characteristics such as height, horizontal and vertical sync.
Use the specified test equipment or its equivalent.
Correct impedance matching is essential.
Avoid overload. Excessive signal from a sweep generator might overload the front-end of the TV. When inserting signal markers, do not allow the marker generator to distort test result.
Connect the TV only to an AC power source with voltage and frequency as specified on the back cover nameplate.
Do not attempt to connect or disconnect any wire while the TV is turned on. Make sure that the power cord is disconnected before replacing any parts.
To protect against shock hazard, use an isolation transformer.
Entering Factory Mode
To enter ‘Service Mode’ Press the remote -control keys in this sequence:
The buttons are active in the service mode.
1. Remote - Control Key : Power, Arrow Up, Arrow Down, Arrow Left
Arrow Right, Menu, Enter, Number Key(0~9)
2. Function - Control Key : Power, CH +, CH -, VOL +, VOL -,Menu, TV/VIDEO(Enter)
Panel Check
You have to check Panel Maker Because of different adjustments as follows.
First of all, check the label rating
Label Rating File
- LCD PANEL MARK
A:ACER(AUO),S : SEC, C : CMO
* If not printed you could consider S(sec) panel mark.
Factory Data
Option Table (Service)
WB Adjust
Information
Checksum
T-CRL32PEUMD-XXXX (Main Micom Ver.)
T_NHBTEDEUC-xxxx (DTV MICOM Ver.)
EDID: L12_1366_768 Success
HDCP Success
Month/Day/Year Hour/Min./Sec.
Advanced Menu
Color Calibration
Adjust spec.
1. Source: HDMI
2. Setting Mode: 1280*720@60Hz
3. Pattern: Pattern #24 (Chess Pattern)
Use Equipment: CA210 & Master MSPG925 Generator
Use other equipment only after comparing the result with that of the Master equipment.
Method of Color Calibration (AV)
1) Apply the NTSC Lattice (N0. 3) pattern signal to the AV IN 1 port
2) Press the Source key to switch to “AV1” mode
3) Enter Service mode
4) Select the “Calibration” menu
5) Select the “AV Calibration” menu.
6) In “AV Calibration Off” status, press the “ ” key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the “AV Calibration” status from Failure to Success.
Method of Color Calibration (Component)
1) Apply the 720p Lattice (N0. 6) pattern signal to the Component IN 1 port
2) Press the Source key to switch to “Component1” mode
3) Enter Service mode
4) Select the “Calibration” menu
5) Select the “Comp Calibration” menu.
6) In “Comp Calibration Off” status, press the > key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the “Comp Calibration” status from Failure to Success.
Method of Color Calibration (PC)
1) Apply the VESA XGA Lattice (N0. 21) pattern signal to the PC IN port
2) Press the Source key to switch to “PC” mode
3) Enter Service mode
4) Select the “Calibration” menu
5) Select the “PC Calibration” menu.
6) In “PC Calibration Off” status, press the >key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the “PC Calibration” status from Failure to Success
Method of Color Calibration (HDMI)
Apply the 720p Lattice (N0. 6) pattern signal to the HDMI1/DVI IN port
2) Press the Source key to switch to “HDMI1” mode
3) Enter Service mode
4) Select the “Calibration” menu
5) Select the “HDMI Calibration” menu.
6) In “HDMI Calibration Off” status, press the > key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the “HDMI Calibration” status from Failure to Success.
White Ratio (Balance) Adjustment
You can adjust the white ratio in factory mode (1: Calibration, 3:White-Balance)
The optimal values for each mode are configured by default. (Refer to Table)
It varies with Panel’s size and Specification.
Equipment : CS-210
- Pattern: MIK K-7256 #92 “Flat W/B Pattern” as standard
- Use other equipment only after comparing the result with
that of the Master equipment.
- Set Aging time : 60min
Calibration and Manual setting for WB adjustment.
HDMI : Time #6 720P, Pattern #24 Chessboard Calibration === Manual adjustment #92 pattern (720p)
COMP: Time #6 720P, Pattern #24 Chessboard Calibration ===Manual adjustment at #92 pattern (720p)
CVBS: Time #2 PAL, Pattern #24 Chessboard Calibration === Manual adjustment at #92 pattern (NTSC)
PC: Time #21 1024*768, Pattern #24 Chessboard Calibration === Manual adjustment at #92 pattern (NTSC)
- If finishing in HDMI mode, adjustment coordinate is almost same in AV/COMP mode.
- White Balance Manual Adjustment
How to Access Service Mode after S/W Upgrade
Entering Factory Mode
<Power OFF> <INFO> <MENU> <MUTE> <Power ON>
Factory Data
Option Table(Service)
WB Adjust
Information
Advanced Menu
If you want to enter here, press “0000”.
How to Initialize
Click “1. Option Table(Service)” → “Factory Reset” in Factory Menu.
You can make every setting in Factory Initial Status.