HBD-DZ330 - DZ710 - DZ730 are the amplifier, DVD-CD and tuner section in DAV-DZ330-DZ710-DZ730.
Model Name Using Similar Mechanism:
HBD-DZ170-DZ171-DZ175-DZ310-DZ510-DZ610-DZ810.
Mechanism Type: CDM85MB-DVBU102.
Optical Pick-up Name: KHM-313CAA.
Amplifier Section power output: Front L + Front: 108 W + 108 W (at 3 ohms, 1 kHz, 1% THD)
Self-diagnosis Function.
(When letters-numbers appear in the display)
When the self-diagnosis function is activated to prevent the system from malfunctioning, a 5-character service number (e.g., C 13 50) with combination of a letter and 4 digits appears on the TV screen or front panel display. In this case, check the following table.
When the version number appears on the TV screen.
When you turn on the system, the version number [VER.X.XX] (X is a number) may appear on the TV screen. Although this is not a malfunction and for Sony service use only, normal system operation will not be possible. Turn off the system, and then turn on the system again to operate.
How to open the disc table when power switch turns off Insert a tapering driver into the aperture of the unit bottom, and slide it in the direction of the arrow.
Insert a screwdriver from between the front panel and the chassis and slide the rod in the direction of the arrow.
Precaution when installing a new OP unit-Precaution before unsoldering the static electricity prevention solder bridge.
When installing a new OP unit, be sure to connect the flexible printed circuit board first of all before removing the static electricity prevention solder bridge by unsoldering. Remove the static electricity prevention solder bridge by unsoldering after the flexible printed circuit board has already been connected.
(Do not remove nor unsolder the solder bridge as long as the OP unit is kept standalone.)
NOTES ON HANDLING THE OPTICAL PICK-UP BLOCK OR BASE UNIT
The laser diode in the optical pick-up block may suffer electrostatic break-down because of the potential difference generated by the charged electrostatic load, etc. on clothing and the human body. During repair, pay attention to electrostatic break-down and also use the procedure in the printed matter which is included in the repair parts. The flexible board is easily damaged and should be handled with care.
NOTES ON LASER DIODE EMISSION CHECK
The laser beam on this model is concentrated so as to be focused on the disc reflective surface by the objective lens in the optical pickup block. Therefore, when checking the laser diode emission, observe from more than 30 cm away from the objective lens.
LASER DIODE AND FOCUS SEARCH
1. Open the case and turn POWER on with no disc inserted.
2. Confirm that the following operation is performed while observing the objecting lens from the clearance of DVD mechanism deck.
1) Confirm that laser beam is spread.
2) Up and down motion of the objective lens. (2 times)
DISC TRAY LOCK
The disc tray lock function for the antitheft of an demonstration disc in the store is equipped.
1. Press the POWER button to turn the set on.
2. Press the [FUNCTION] button to set DVD/CD function.
3. Insert a disc.
4. Press the [STOP] button and the [EJECT] button simultaneously for five seconds.
5. The message “LOCKED” is displayed and the tray is locked.
Releasing Procedure:
1. Press the [STOP] button and the [EJECT] button simultaneously for five seconds again.
2. The message “UNLOCKED” is displayed and the tray is unlocked.
Note: When “LOCKED” is displayed, the tray lock is not released by turning power on/off with the [POWER] button.
IMPORTANT NOTICE
Caution: This system is capable of holding a still video image or onscreen display image on your television screen indefinitely. If you leave the still video image or on-screen display image displayed on your TV for an extended period of time you risk permanent damage to your television screen. Projection televisions are especially susceptible to this.
Discharge the charged electricity in capacitors to prevent electric shock as follows
When disassembling the machine, be sure to discharge the charged electricity in the following capacitors. Use a resistor of 800 ohms, 2 Watts for discharging the following capacitors.
TEST MODE
Note: Incorrect operations may be performed if the test mode is not entered properly. In this case, press the [POWER] button to turn the power off, and retry to enter the test mode.
1. Cold Reset
• The cold reset clears all data including preset data stored in the RAM to initial conditions. Execute this mode when returning the set to the customers.
1. Press the [POWER] button to turn the power on.
2. Press three buttons [PLAY], [FUNCTION] and [POWER] simultaneously.
3. When this button is operated, display as “COLD RESET” for a while and all of the settings are reset.
2. Panel Test Mode
• This mode is used to check the software version, FL and KEY.
Display Test Mode
1. Press the [POWER] button to turn the power on.
2. While pressing the [STOP] and the [PLAY] buttons simultaneously, turn the [VOLUME] control in the direction of (+).
3. When the display test mode is activated, all segments are turned on. When the mode in, “REC TO USB” is turn off.
4. To exit from this mode, while pressing the [STOP] and the [PLAY] buttons simultaneously, turn the [VOLUME] control in the direction of (+).
Version Test Mode
1. When the display test mode is activated, press the [FUNCTION] button and the message “DSZ2E” (DZ330), “DSZ6KD” (DZ710), “DSZ5E” (DZ730) are displayed, the version test mode is activated.
2. Whenever the [FUNCTION] button is pressed, the display changes in the following order.
3. Press the [REC TO USB] button when the MC version is on display. The date of software production is displayed.
4. Press the [REC TO USB] button again and the version is displayed.
5. To exit from this mode, while pressing the [STOP] and the [PLAY] buttons simultaneously, turn the [VOLUME] control in the direction of (+).
FL Pattern Test Mode
1. When the display test mode is activated, press the [EJECT] button, to select the FL pattern test mode. When the FL pattern test mode, half segments of FL display and “REC TO USB” are turn on.
2. Press the [EJECT] button, half segments of FL display and “REC TO USB” are turn off.
3. Next press the [EJECT] button, all segments of FL display is turn on.
4. To exit from this mode, while pressing the [STOP] and the [PLAY] buttons simultaneously, turn the [VOLUME] control in the direction of (+).
Key Test Mode
1. When the display test mode is activated, press the [?/1] button, to select the key test mode.
2. To enter the KEY test mode, the fluorescent indicator displays “K0 V0”. Each time an another button is pressed, “KEY” value increases. However, once a button is pressed, it is no longer taken into account. When all keys are pressed correctly, “K6 V0” is displayed.
3. When the [VOLUME] control is turned in the direction of (+), “V0” is changed to “V1”, then ... “V9”. When the [VOLUME] control is turned in the direction of (–), “V0” is changed to “V9”, then ... “V1”.
4. To exit from this mode, while pressing the [STOP] and the [PLAY] buttons simultaneously, turn the [VOLUME] control in the direction of (+).
DVD Version Display
• The STR and DVD microprocessor versions are displayed.
1. Press the [POWER] button to turn the set on.
2. Press the [PLAY] button and the [POWER] button simultaneously for three seconds. SC version display is presented.
3. Pressing the [FUNCTION] button presents a DV version display. Pressing the [FUNCTION] button again returns to the SC version display.
4. To exit from this mode, press any button other than the [FUNCTION] button.
Product Out
• This mode moves the optical pick-up to the position durable to vibration and clears all data including preset data stored in the STR RAM to initial conditions. Use this mode when returning the set to the customer after repair.
1. Press the [POWER] button to turn the power on.
2. Press the [FUNCTION] button to set the function “DVD/CD”.
3. Remove all discs.
4. While pressing the [STOP] and the [EJECT] buttons simultaneously, turn the [VOLUME] control in the direction of (+).
5. Displayed to message “SERVICE IN” on the fluorescent indicator tube when pressing in turn the [4] > [DVD MENU] > [CLEAR] buttons on the remote commander.
6. After the “STANDBY” blinking display finishes, the message “MECHA LOCK” ó “UNPLUG” is displayed on the fluorescent indicator tube disconnect the AC power plug, then the product out mode is set.
The STR RAM initialization is executed upon a next power-on after the power is turned off.
Power board schematic
D.C.A.C. (AUTOMATIC ACOUSTIC FIELD CALIBRATION) TEST MODE
1. Press the [POWER] button to turn the power on.
2. Press the [FUNCTION] button to set the function “ DVD-CD”.
3. Insert Calibration mic (ECM-AC2) supplied as an accessory into the A.CAL MIC jack.
4. Press three buttons [x], [Z] and [REC TO USB] simultaneously.
5. Confirm that the following are shown on the display panel.
The JACK inserted/non-inserted detection display and the display.
1 MIC detection condition
NON : Not detected
IN : Detected
2 Presence of DIGITAL sound data input to the microprocessor
NG: Input absent
OK: Input present
3 AD value (255h) of MIC input to the microprocessor.
6. To exit from this mode, press three buttons [POWER], [EJECT] and [REC TO USB] simultaneously.
7. PROTECTION FACTOR (SD DETECTION-DC DETECTION-TSD DETECTION) IDENTIFICATION TEST MODE
When an error is detected, the FL tube alternately displays
“PROTECTOR< -> PUSH POWER”.
Press the [POWER] button.
* Buttons other than the [POWER] button are invalid.
“STANDBY” blinks three times on the FL tube.
The protection release state (POWER OFF) is established.
(No FL tube display)
Press the [POWER] button two times.
The power to the system turns on, and the normal operation is established. (Restore).
During the protection state:
1. If the AC plug is connected or disconnected during the protection state, the protection state is released, and the normal operation is established. (The protection state is not maintained.)
2. The protection factor is displayed by pressing the [RETURN] > [3] > [2] > [0] > [0] > [ANGLE] buttons of the remote commander.
(During the “PROTECTOR” > “PUSH POWER” display).
When SD is detected: Repeats
“SD DETECT” > “PROTECTOR”.
When DC is detected: Repeats
“DC DETECT” > “PROTECTOR”.
When TSD is detected: Repeats
“TMP DETECT” > “PROTECTOR”.
PL: SD detection
When the “L” output from the SD (shutdown) port on the S-MASTER POWER Driver Shutdown and voltage descent (15V or less) of 30V power supply (PVDD) are detected.
DC detection
When the “L” output from the power/speaker error detection circuit (DC detection port) is detected for two seconds continually, the power system other than that of the FL tube is turned off, and the protection state is established.
TSD detection
When the “L” output from the thermal shutdown port (TSDM) on the motor driver is detected.