DURABAND - DBVT1341 Series A & MEMOREX [SERVICE MODE]
TO ENTER SERVICE MODE
The unit provides with the following Service Modes, so you can repair, examine and adjust easily.
- Unplug the AC cord till lost all clock time.
- Press and Hold "Vol-" button on the front panel of the TV & remote control unit simultaneously.
- The both pressing of set key and the remote control key will not be possible if clock has been set.
CONFIRMATION OF HOURS USED
- Set the Volume to Minimum.
- While holding down Volume button on the front cabinet, press key [6] on the remote control simultaneously.
- After confirming of using hours, turn Off Power.
DISPLAY Window.
INIT 00 83 => INITIAL SETTING CONTENT OF ,MEMORY IC.
POWER ON 0010 => POWER ON TOTAL HOURS.
PLAY/RECORD => PLAY/RECORD TOTAL HOURS.
[16*16*16*thousand digit value] + [ 16*16*hundreds digit value] + [16* tens digit value] + [ones digit value]
SET KEY => REMOTE KEY => OPERATIONS.
Volume Minimum => 0 => Releasing of V-Chip password.
Vol min => 1 = Initialization of factory ( Do not use this for normal service).
Vol min => 2 => Horizontal position of OSD.
Vol min => 3 => Adjust the PG shifter automatically.
Vol min => 4 => Adjust the PG sifter manually.
Vol min => 5 => Adjusting the tracking to center position.
Vol min => 6 => Power On total hours and Play|Record total hours displayed on the screen.
Vol min => 8 => Writing of EEPROM initial data. (do not use this for normal service).
Vol min => 9 => Display of adjustment menu on screen.
METHOD => OPERATIONS
Method: Press the ATR button on the remote control for more than 2 seconds during PLAY.
Operation: Adjusting the tracking to center position.
Method: make a short circuit between the test points of "Service" and Ground"
Operation: The EOT | BOT | REEL SENSOR do not work at this moment.