PIONEER - PDP5071PU Plasma TV SERVICE FACTORY MODE
How to enter Service Mode to Pioneer Plasma TV PDP5071PU
TO ENTER | EXIT SERVICE FACTORY MODE- Case operated by remote control.
- Service Remote Control: press "Factory"
Case to RS-232 transmit command.
- Standby Mode: Send [PON] + [FAY].
- Power supply ON mode: Send [FAY].
To Exit from service mode.
Case operated by remote control
- Service remote control: press [FACTORY] key.
- Remote control: Press [HOME MNU] key.
Case to RS-232 transmit command
- Send [FAN].
OPERATION OF SERVICE FACTORY MODE
- The settings for the following functions are set to OFF when Service Factory Mode is entered; including when the "FAY" command is received.
Number => Function => Remarks
- = > Two screen operation => Input function set on the main side is selected.
- => FREEZE => ........=> ...........
- => Mask control => MTB | MB is none. It becomes processing on the PANEL side.
- => ORBITER => Central value operation.
- => Detection of the TRAP switch => The detection operation is stopped.
- => TRAP history => To a possible turning on through the memory is maintained.
- => Display TV guide => ..... => .....
- => Setting of Parential Control => When this is turned off, the block of the screen is released.
[Enter the Factory after cancelling "ACI'" because, the ACI operation setting OFF and not done.]
USER DATA
- User data on picture- and audio-quality adjustments are not reflected , and the factory preset data are output. User data will be retained in memory. When unit enters Service Factory Mode, the current audio-quality adjustment data will be send be retained in memory.
- As to data on various settings, user data will be applied to the items that are associated with signal format change; screening, switching, etc.
- Data on screen , ie, Screen position, Meaning clock dividers, and not including data on screen size, are reset to default values(data stored in memory will be retained). Screen size will be retained.
REMOTE CONTROL CODES IN SERVICE FACTORY MODE
*********************************************************************************
SR |R KEYS => BASIC FUNCTIONS => REMARKS
*********************************************************************************
Muting => Switching the main items => Shifting to next main item [top]
Down => Switching sub-title items => Switching downward to the next sub-titled item.
UP => Switching the sub-title items => Shifting upwards to the next upper layer
Left => Decreasing the adjustment value => Decreasing the adjustment value.
Right => Increasing the adjustment value => increasing the adjustment value.
Enter | Set => Switching the layers => Shifting downward or upward to the next lower or upper layer.
INPUT => Selecting Input => Shifting the input to next function.
INPUTxx => Selecting input => Switching the input to xx. [xx=1-6 etc].
CH+| P+ => increasing the channel number.
CH- | P- => Decreasing the channel number.
Numeric keys => Function TV => Function TV 9previously selected channel number is selected)
POWER => Power off => Turning the Power Off.
FACTORY => Factory Off(factory mode) => In factory mode, turning factory mode Off.
FACTORY => Factory On (Non-Factory mode) => In Non-Factory mode, turning factory mode ON.
HOME MENU*1 => Menu On => in factory mode, turning factory mode Off, and menu mode On.
VOLUME+ => Volume Up => Increasing 10 the adjustment value. {Panel Factory}
VOLUME - =. Volume Down => Increasing 10 the adjustment value {Panel Factory}
DRIVE ON | OFF*2 => Drive Mode Off => Turning drive mode Off.
INTEGRATOR*1 => Integrator Menu On => Enter integrator mode.
*********************************************************************************
* A pertinent key that exists in the Service Remote control, becomes effective only in the Factory and Integrator mode.
** When ten seconds have passed
since the [DRIVE ON|OFF] key was pressed at the standby, it becomes
invalid. Press "Power" key from the [DRIVE ON|OFF] key pressing within
ten seconds when you do power supply ON while driven OFF.
__________________________________________________________________