SHARP LC-26AF3 _ LC-32AF3 _ LC-37AF3 _ ADJUSTMENT PROCEDURE _ PROGRAM RE-WRITING PROCEDURE
The adjustment values are set to their optimum at the factory before shipping. If by any chance a value should become improper or a readjustment is required due to part replacement, make an adjustment according to the following procedure.
Before adjustment, perform aging for approx. 60 minutes to stabilize the unit.
AFTER REPLACEMENT OF ANY PWB AND/IC FOR REPAIR, NOTE THE FOLLOWING
- When replacing the following units, be sure to prepare the new units loaded with updated software.
DUNTKD304DE07/08/10
(LC-26AF3M/H/X)
DUNTKD304DE01/02/03
(LC-32AF3M/H/X)
DUNTKD304DE04/05/06 (LC-37AF3M/H/X)
MAIN UNIT
DUNTKD186FE06
(LC-26AF3M/H)
DUNTKD186FE07
(LC-26AF3X)
DUNTKD186FE08
(LC-32AF3M/H)
DUNTKD186FE10
(LC-32AF3X)
DUNTKD186FE04
(LC-37AF3M/H)
DUNTKD186FE05 (LC-37AF3X)
PROGRAM RE-WRITING PROCEDURE
PREPERATION
- PC with parallel port (printer port)
- Parallel cable (Straight type)
- Jig PWB (PAL JIGUIF-001)
- 20-pin cable Application software for the rewriting program (IAP Writer)
- Rewriting program.
- Set the PC printer port to EPP or ECP from BIOS setting. (Settings are different depending on PCs; it is desirable that a skilled person performs this operation.)
- Install the application software for the rewriting program (IAP Writer) into the PC.
- Connect the PC and the jig PWB with the parallel cable.
- Rewrite the program.
- Unplug the AC cord during power up.
- Connect the jig PWB and the main PWB with the cable (20-pin). (Connect P5601 of the jig PWB and P2001 of the main PWB.)
- Start the application software for the REWRITING program (IAP Writer). (If start-up is impossible, recheck the procedure.)
- While holding down the TV system reset button, plug in the AC cord to turn on the power. LED on the jig PWB lights up. Jig PWB connection is automatically detected and the system is shifted to the program rewriting mode.
- The rewriting program (IAP Writer) on the PC dictates writing. (Writing conditions are indicated on the IAP Writer.)
- Wait until Step 5 is ended.
- When ended, exit the IAP Writer.
- Turn off the AC power of the unit. (Unplug the AC cord.)
- Remove the cable from the jig PWB and the main PWB.
- Turn on the Ac power of the unit to check for operation. (If INPUT SELECT and volume control are available, rewriting is completed.).
ENTERING AND EXITING ADJUSTMENT PROCEDURE
- Before entering the adjustment process mode, press the "RESET” button or adjust the menu image to reset the AV position.
- Unplug the AC power cord of the running TV to force off the power.
- While holding down "VOL (-)" and "TV/VIDEO" keys at once, plug in the AC power cord to turn on TV. The letter K appears on the upper left of the screen.
- Next, hold down the "VOL (DN)" and "CH (UP)" keys at once. Multiple lines of blue characters appearing onscreen indicate that the unit is now in the adjustment process mode. If you fail to enter this mode (the display is the same as normal startup), retry the procedure.
- To exit the adjustment process mode after adjustment is completed, unplug the AC cord to force off the power. (When the power is turned off with the remote control, once plug the AC cord and after approx. 10 seconds plug it in again.).