SHARP LC-32AX5H/M/X _ ADJUSTMENTS _ PUBLIC MODE SETTING _ FACTORY SETTING
ADJUSTMENT PROCEDURE [ENTERING INTO ADJUSTMENT PROCESS MODE]
- While holding down the TV/VIDEO and Volume DOWN keys at the same time, set the Power switch to ON. (“K” standing for inspection process mode is displayed in the upper left portion of the screen.)
- Press the Channel DOWN and Volume DOWN keys at the same time. (The adjustment process mode screen appears.)
- To cancel it, turn off the power using the Power switch or remote control.
KEY OPERATION IN ADJUSTMENT PROCESS MODE
- Tune in to a station using the Channel UP/DOWN keys.
- Switch the input using the TV/VIDEO key.
- Select an item to adjust using the Cursor UP/DN keys. (Pressing the Cursor [DN] key while at the bottom item moves to the top item on the next page, and pressing the Cursor [UP] key while at the top item moves to the bottom item on the previous page.)
- Adjust the item selected using the Volume +/– or Cursor [LEFT/RIGHT] keys.
- Press the Menu key to move to the next item. (Pressing the Menu key while at the bottom item moves to the top item on the next page.).
LAYER MOVEMENT
- Pressing the ENTER key while at an item other than I2C DATA and HOTEL POWERFIX on page 2 moves to the setting page of that item name.
- Press the Flashback key to exit each setting page.
INITIALIZATION
Connect the pins 81 and 82 of IC2001
(microprocessor), then turn on the power.
Check MODEL (A648MB).
Check INCH
SIZE.
MODEL: LC-32AX5H/M/X
INCH
SIZE: 32
ADJUSTMENTS
AD
converter level adjustment: 1080i input.
Adjustment Conditions: 1080i 75% colour bar signal input Used device name: LEADER
LT448 Signal name: COLOUR BAR
- Use the LT-448-compatible third one of three color bars. Setting value: 02: 1080i/59.93 (30 sF) H: 33.72 kHz, V: 29.97 Hz.
- ADJUSTMENT PROCEDURE: Set AUTO GAIN-OFFSET on page 3 (M2-HD) of the adjustment process DVP hierarchy to ON.
=================================================================================
480i INPUT
ADJUSTMENT CONDITIONS: 480i 75% colour bar signal input Used
device name: LEADER LT448 Signal name: COLOUR BAR
Use the LT-448-compatible third one
of three color bars. Setting value: 15: 480i/60 H: 15.73 kHz, V: 29.97 Hz.
- ADJUSTMENT PROCEDURE: Set AUTO GAIN-OFFSET on page 4 (M2-SD) of the adjustment process DVP hierarchy to ON.
=================================================================================
ADJSUTMENT CONDITION: Receive the PAL standard color bar signal.
- If the maximum value of “PAL TAMP1” on page 1 of adjustment process DVP hierarchy is not in the range of values in the list below, adjust “PAL TAMP1” on the same page so that the maximum value of “Y” is in the range of values in the list below.
Note that the setting value may vary by model.
- When pressing the TAMP1 direct keys, adjustment of “PAL TAMP1” is complete. Then, The values of “NTSC TAMP1” and “SECAM TAMP1” are automatically set.
(NTSC: Value of PAL –7, SECAM: The
same value as PAL).
================================================================================
WHITE BALANCE ADJUSTMENT: Adjust the white 144 gradation using
RGB CUTOFF2 and then the white 73 gradation with RGB-GAIN.
TEST SIGNAL ADJUSTMENT
- [Input signal] : Display the WB test signals with built-in DVP of white 56% (144 gradations) and 29% (73 gradations) on the left and right of the screen respectively by using the remote control code “011110010001010”.
[Adjustment value]:
- White 56% x = 0.261 ±0.004 ±0.01 Radius from the center point x = 0.277 ±0.004 ±0.01 Radius from the center point.
- White 29% x = 0.261 ±0.002 ±0.01 Radius from the center point x = 0.277 ±0.002 ±0.01 Radius from the center point.
[Adjustment method by bus]:
- Cutoff: RGB CUTOFF2 G CUTOFF2 = Fixed to 0. Vary RB CUTOFF2: Adjustment range: ±30.
- Gain: RGB-GAIN G-GAIN = Fixed to 0. Vary RB-GAIN. Adjustment range: ±30.
(The adjustment value is measured
with MINOLTA CA-210 and the correction mode is measured in the mode compatible
with CH02 “TOPCON”.)
- Perform the factory setting using the remote control for adjustment. (This setting must be done after performing the MCL data setting.)
- “H” standing for factory setting 1, “M” standing for factory setting 2 or “X” standing for factory setting 3 is displayed in the upper left portion of the screen by continuing to press the Factory Setting key on the remote control for adjustment.
- When “SETTING COMPLETE” is displayed in the middle of the screen after a few seconds, setting is complete.
- Turn off the power
NOTE: Set the Power switch to “OFF”
immediately after completing the factory setting.
PUBLIC MODE SETTING
There are
the following two ways to get the public mode setup screen displayed.
- Press the “INPUT” and “VOL (+)” keys on the set at once and turn on the power.
- Get the password input screen displayed.
PROCEDURE
- The input starts with the leftmost digit.
- Use the numeric keys [1] thru [9] and [10/0] keys on the remote controller. The other keys are not acceptable.
- With a numeric-key input, “–” will change to “ * “. The input position will move one digit to the right.
- With all the 3 digits entered, the password will be verified.
- The 3-digit password is now verified.
- The password [0] [2] [7] provides for the public mode screen. (This screen comes on with whatever adjustment process settings.)
- With any other passwords, the screen changes to the normal mode.
In the
adjustment process mode, turn on “PUBLIC MODE”. Also press the “CH ( UP )” and
“VOL (+)” keys on the set at once and turn on the power.
TO EXIT PUBLIC MODE
There are the following ways to quit
the public mode setup screen.
- Turn off “PUBLIC MODE” in the adjustment process mode. ( * ) This way alone is not for quitting the setup screen, but for quitting the mode itself.
- Turn off the power with the “POWER” key. ( * )
- Select “ENTER”. ( * )
- Move the cursor to “RESET” and press the “FLASHBACK” key. (Back to the normal mode screen) ( * ).
PUBLIC MODE SETTING VALUES
With the factory settings made, the public mode
settings get initialized. (The adjustment process remains intact.)