SONY TRINITRON - KV27FS KV32FS KV34FS KV36FS KV32FS SERIES - BLINKING CODES
APPLICABLE TO [SONY- KV-27FS320_KV-32FS120_KV-32FS320_KV-34FS120_KV-36FS120_36FS320_KV-38FS120]
If an error occurs, the STANDBY/TIMER LED will automatically begin to flash. The number of times the LED flashes translates to a probable source of the problem. A definition of STANDBY/TIMER LED flash indicators are listed here for reference. If an error symptom cannot be reproduced, the remote commander can be used to review the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Results for all of the following diagnostic items are displayed on screen. No error has occurred if the screen displays a [0].
* If a +B over-current is detected, stoppage of vertical deflection is detected simultaneously. The symptom that is diagnosed first by the micro-controller is displayed on the screen.
====================================================================
Diagnostic item description
|
No. of times Standby/Timer lamp flashes
|
Self-diagnostic display/diagnostic result
|
Probable cause location
|
Detected symptoms
|
Power does not turn ON
|
Does not light
|
===========
|
# Power cord is not plugged in. # Fuse is burned [F601 –
A-board].
|
# Power does not come on.
# No power is supplied to TV.
# AC power supply is faulty.
|
+B overcurrent (OCP)
|
2 times
|
2:0 or 2:1
|
# H.Out (Q502) is shorted [A-Board] # IC702 shorted [C-Board].
|
# Power does not
turn ON. # Load on poser line is shorted.
|
I-Port
|
4 times
|
4:0 or 4:1
|
# +13V is not supplied [A-Board]. # IC 561 is faulty
[A-Board].
|
# Has entered standby state after horizontal raster. #
Vertical deflection pulse is stopped. # Power line is shorted or power supply
is stopped.
|
Ik (IKB)
|
5 times
|
5:0 or 5:1
|
# IC 1001 faulty [M-Board. # Screen (G2) is improperly
adjusted.
|
# No raster is generated.
# CRT cathode current detection reference pulse output is small.
|