Samsung PS42E7SX-XEC – 42 inch and 50 inch Plasma TV – power supply board voltages
Power ON/OFF Signal Description1. When connecting the AC power cord, Stand-By 5V from the Main SMPS is supplied to the Main Board (Pin 3 of CN1002 of Main Board).
2. When pressing the Power button on the remote control or on the main body, PS_ON (Pin 5 of CN1002 of Main Board) changes from High to Low.
3. If the PS_ON signal changes to Low, the Main SMPS supplies power to the Main Board and Logic Board, and Va and Vg power is supplied to the DC-DC SMPS.
4. If the VS_ON signal from the Logic Board changes from Low to High, the Main SMPS supplies VS power to the X and Y Main Board through the DC-DC SMPS, and the screen displays a picture on it.
Main
SMPS
Outline
(PDP 42inch/50inch SMPS)
Considering various related conditions, the switching regulator with good efficiency and allowing for its small size and light weight was used as the power supply for PDP 42inch/50inch, VS requiring high power consumption Asymmetrical Half Bridge converter and flyback converter. To comply with the international harmonics standards and improve the power factor, active PFC(Power Factor Correction) was used to rectify AC input into +400V DC output, which in turns used as input to the switching regulator.
Considering various related conditions, the switching regulator with good efficiency and allowing for its small size and light weight was used as the power supply for PDP 42inch/50inch, VS requiring high power consumption Asymmetrical Half Bridge converter and flyback converter. To comply with the international harmonics standards and improve the power factor, active PFC(Power Factor Correction) was used to rectify AC input into +400V DC output, which in turns used as input to the switching regulator.
Input
The power supply shall be capable of supplying full rated output power over free voltage ranges that are rated 100 VAC - 240 VAC RMS nominal. Operating voltage : 90 VAC - 264 VAC
The power supply must be able to start up under peak loading at 90V AC. The power supply shall automatically recover from AC power loss. (Note that nominal voltages for test purposes are considered to be with +/- 1.0V of nominal). STD_5V & Vpr2(3.3V) is a SELV standby voltage that is always present when AC mains voltage present.
The power supply shall be capable of supplying full rated output power over free voltage ranges that are rated 100 VAC - 240 VAC RMS nominal. Operating voltage : 90 VAC - 264 VAC
The power supply must be able to start up under peak loading at 90V AC. The power supply shall automatically recover from AC power loss. (Note that nominal voltages for test purposes are considered to be with +/- 1.0V of nominal). STD_5V & Vpr2(3.3V) is a SELV standby voltage that is always present when AC mains voltage present.
Over
Voltage Protection
The over voltage sense circuitry and reference shall reside in package that are separate and distinct from the regulator control circuitry and reference. No single point fault shall be able to cause a sustained over voltage condition on any of all outputs. The supply shall provide latch-mode.
The over voltage sense circuitry and reference shall reside in package that are separate and distinct from the regulator control circuitry and reference. No single point fault shall be able to cause a sustained over voltage condition on any of all outputs. The supply shall provide latch-mode.
Short
Circuit and Over current Protection
An
output short circuit is defined as output impedance of less than 300mohms. The
power supply shall shutdown and latch off for shorting VS DC rails to return.
Shorts between main output rails and STD_5V shall not cause any damages to the
power supply. The power supply shall
either shutdown and latch off for shorting is removed, the P/S shall recover.
The power supply shall be capable of withstanding a continuous short-circuit to
the output without damage or over stress to the unit (components, PCB
traces,connectors,etc.)
SMPS
board voltages
DC-DC SMPS Board voltages
Click on the pictures to zoom in