REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Tuesday, 26 February 2019

SHARP - LC 32D50U ADJUSTMENT PROCEDURE SOFTWARE UPGRADE


SHARP - LC 32D50U ADJUSTMENT PROCEDURE SOFTWARE UPGRADE

SHARP   LC 32D50U _ LCD TV

     The adjustment values are set to optimum conditions at the factory before shipping.  If a value should become improper of an adjustment is required due to parts replacement, make an adjustment according to the following procedure.

     When replacing the following units, make sure to prepare the new units loaded with updated software.

  • Main unit => DUNTKD640FMM13
  • IF Unit => DUNTKD643FM13
UPGRADING OF EACH MICROPROCESSOR SOFTWARE

     Never Power OFF the unit, when software upgrade is ongoing; otherwise the the system may be damaged beyond recocvery.

Software Version Upgrade

The model employs the following software.
  • Main software.
  • Monitor Microprocessor software.
     The main and monitor software can be upgraded by using a general purpose SD memory card.
The followings are the proceedings for upgrading.

MAIN SOFTWARE UPGRADE
You need:
  1. SD memory card of 32MB or higher capacity.
  2. PC running on Windows 98/98SE/ME/2000/XP operating system.
  3. SD memory card reader/writer with USB connectivity.
  4. SD memory card formatting software.
     To upgrade the main software, it is necessary to get ready the SD card for version upgrade.
Follow these steps and create the SD card for version upgrade.
  • Insert the SD card in to the SD card reader/writer.  Start the SD card formatting software, and click format.  When you have the drive options, select the drive where the SD card is inserted before you proceed.
  • When the formatting is over, click OK at the complete window.
  • Click Exit to finish formatting.  When you have done, take out the SD card once to make sure it is finished. Insert it again.
  • Copy the Binary image file [D50UAxxx.SDC], named temprorarily, for version upgrade to the root directory/folder of the SD card drive. [Note that, the SD card drive do not store the other folders or unrelated files, or more than one Binary Image files for version upgrade.]  Now the SD card version for upgrade is ready. 
HOW TO UPGRADE THE SOFTWARE.
  • Shut down AC Power.
  • Insert the SD card for version upgrade; prepared as above; into the service socket located lower side from the center at terminals , above S-Video terminal in the rear of the unit, in a way that the cut corner of the SD card comes at the upper side. [If the SD card inserted in a wrong way, the card will go deep inside the unit beyond retrieval.  Take care to insert SD card correctly.
  • Turn ON the AC Power.
  • After the unit start up, the system upgrade screen will appear withing 25 to 50 seconds.
  • Even a single failure in the process will trigger the upgrade failure screen.  The word "NG" changes to Red for the item failed. (In event of failure, repeat the upgrading process.  If the process repeatedly fails, it is likely that the hardware is troubled.
  • Up on completion of the whole process, the upgrade success screen will appear.  You can check the new software version on this screen.  The version information only appear after the upgrade is complete.  
  • Shut OFF the AC Power to the unit, and remove the SD card from the slot.
  • Now the software upgrade is complete. 
     When you've done with the software version upgrade, start the set, go to the top page of the adjustment process and check the main software version information.

MONITOR MICROPROCESSOR SOFTWARE VERSION UPGRADE

     If the Monitor Version in the process menu is "2.00M", the monitor microprocessor software cannot be written, because, IC2002 has been replaced with the mask type. 
  • Get ready the same items as listed in the Mains software version upgrade.
  • Create the SD card for monitor microprocessor software version upgrade, in the same manner as explained Main Software Version Upgrade.  Copy the Binary image file M150xxx.SDC; named temporarily; for monitor microprocessor software version upgrade to the SD drive card.
  1. Shut off the AC Power to the unit.
  2. Insert the SD card for version upgrade into the service socket located into the same socket as mentioned above. 
  3. Turn ON the AC power. (The moment this operation is done, the upgrading of the monitor microprocessor software starts.  While the upgrading is ongoing, Never Power Off the unit.  Otherwise the upgrade will fail and the system may have a serious damage beyond recovery )
  4. After unit start up the system upgrade screen will appear within 15 to 40 seconds.
  5. Upon completion of the whole process the upgrade success screen will appear. 
  6. Shut down the AC power, and remove the SD card.
  7. Now the software upgrade is complete.