Panasonic AG-DVX100BP - AG-DVX102BEN to access service mode – How to replace the lithium battery
Panasonic
AG-DVX100BP - AG-DVX102BEN - AG-DVC180BMC – How to access service mode – How to
replace the lithium battery – How to activate diagnostic mode
Panasonic AG-DVX100BP
- AG-DVX102BEN - AG-DVC180BMC
SERVICE
MENU
The SERVICE(CAMERA mode), DIAGNOSTIC(VCR mode) and ADJUST(VCR mode) menu can be displayed as follows.
Press the button in order of “ADUB button” > “STOP button” > “MODE CHK button” > “MENU button”, SERVICE menu in CAMERA mode, DIAGNOSTIC and the ADJUST menu in VCR mode can be displayed in addition to a setup menus.
Next, Tilt the OPERATION lever in the UP( PLAY) or DOWN ( STOP) direction, select the DIAGNOSTIC or ADJUST menu, press SET(STILL) of the OPERATION lever to open the DIAGNOSTIC or ADJUST menu.
The SERVICE(CAMERA mode), DIAGNOSTIC(VCR mode) and ADJUST(VCR mode) menu can be displayed as follows.
Press the button in order of “ADUB button” > “STOP button” > “MODE CHK button” > “MENU button”, SERVICE menu in CAMERA mode, DIAGNOSTIC and the ADJUST menu in VCR mode can be displayed in addition to a setup menus.
Next, Tilt the OPERATION lever in the UP( PLAY) or DOWN ( STOP) direction, select the DIAGNOSTIC or ADJUST menu, press SET(STILL) of the OPERATION lever to open the DIAGNOSTIC or ADJUST menu.
AUDIO
FILTER
ON: The
mechanism noise cancellation function operates by IC3001(DUO).
OFF: The mechanism noise cancellation function does not operates by IC3001(DUO).
Factory default setting is “ON”.
OFF: The mechanism noise cancellation function does not operates by IC3001(DUO).
Factory default setting is “ON”.
DIAGNOSTIC
MENU
How to display the Error Rate.
This unit can be displayed Error Rate and it shows the playing condition of the VCR.
In case of the error rate is displayed, BER DISPLAY and SAMPLE SPEED mode is select on DIAGNOSTIC menu.
How to display the Error Rate.
This unit can be displayed Error Rate and it shows the playing condition of the VCR.
In case of the error rate is displayed, BER DISPLAY and SAMPLE SPEED mode is select on DIAGNOSTIC menu.
Setting
item for LISTA Measurement
ATF GAIN
The speed of the tape changes if this item set to “ON” for the ATF sensitivity confirmation.
After selected “ON”, By pressing SET(STILL) of OPERATION LEVER, enter the adjustment mode and then exit the menu once. The VTR mode is operated when the menu mode is exited temporarily. The screen below is displayed.
NOW SERVO ADJUST
PUSH MENU TO RETURN
It will be returned to ADJUST MENU when the MENU button is pressed in this condition.
ATF GAIN
The speed of the tape changes if this item set to “ON” for the ATF sensitivity confirmation.
After selected “ON”, By pressing SET(STILL) of OPERATION LEVER, enter the adjustment mode and then exit the menu once. The VTR mode is operated when the menu mode is exited temporarily. The screen below is displayed.
NOW SERVO ADJUST
PUSH MENU TO RETURN
It will be returned to ADJUST MENU when the MENU button is pressed in this condition.
LINEARITY
The ATF sensitivity changes if this item set to “ON” for the LINEARITY confirmation.
After selected “ON”, By pressing SET(STILL) of OPERATION LEVER, enter the adjustment mode and then exit the menu once. The VTR mode is operated when the menu mode is exited temporarily. The screen below is displayed.
NOW SERVO ADJUST
PUSH MENU TO RETURN
It will be returned to ADJUST MENU when the MENU button is pressed in this condition
The ATF sensitivity changes if this item set to “ON” for the LINEARITY confirmation.
After selected “ON”, By pressing SET(STILL) of OPERATION LEVER, enter the adjustment mode and then exit the menu once. The VTR mode is operated when the menu mode is exited temporarily. The screen below is displayed.
NOW SERVO ADJUST
PUSH MENU TO RETURN
It will be returned to ADJUST MENU when the MENU button is pressed in this condition
LITHIUM
BATTERY
Replacement
Procedure
1. There is a Lithium battery on the BACK CONNECT C.B.A.
2. Unsolder the Lithium battery and then replace with the new one.
1. There is a Lithium battery on the BACK CONNECT C.B.A.
2. Unsolder the Lithium battery and then replace with the new one.
NOTE:
The
lithium battery is a critical component.
It must never be subjected to excessive heat of discharge.
It must therefore only be fitted in equipment designed specifically for its use.
Replacement batteries must be of the same type and manufacture.
They must be fitted in the same manner and location as the original battery, with the correct polarity contacts observed.
Do not attempt to re-charge the old battery or re-use it for any other purpose.
It should be disposed of in waste products destined for burial rather than incineration.
It must never be subjected to excessive heat of discharge.
It must therefore only be fitted in equipment designed specifically for its use.
Replacement batteries must be of the same type and manufacture.
They must be fitted in the same manner and location as the original battery, with the correct polarity contacts observed.
Do not attempt to re-charge the old battery or re-use it for any other purpose.
It should be disposed of in waste products destined for burial rather than incineration.