ELENBERG
Model: TV-1007
Panel: LQ104V1DG83
MainBoard: JV-508F-A02
Appearance
ELENBERG TV-1007
General recommendations for repairing TV LCD
Possible malfunctions
- ELENBERG TV-1007 does not turn on at all. There is no reaction to the remote control or to the control buttons from the front panel. Indicator lights do not light or flash.
Often in such cases, the power module is faulty. It is necessary to verify the presence of secondary voltages and, if they are absent, check the power switches and rectifier diodes for a short circuit.
In case of breakdowns in the secondary circuits, the converter can operate in a short circuit mode, and during short circuit in the elements of the primary circuit, the main fuse usually breaks.
Mos-Fet keys used in switching power supplies usually fail due to a malfunction of other elements that can put it out of operation in key mode or provoke the excess of maximum current or voltage values. It can be supply, damper circuits, or elements of OOS (negative feedback) stabilization. The reason for the breakdown of the power switch may be PWM (PWM). It is checked only by replacement with a known good one.
- There is no image, there is sound, it is responding to the remote control. Or immediately after turning on for a second, the image may appear and immediately disappear.
These manifestations can be triggered by the power module, or by inverter defects, as well as by the distortion of the currents in the lamps due to their uneven wear. After checking all the electrolytic capacitors of the filters that are involved in the power supply of the inverter, it is necessary to ring in its converter the power switches for breakdown and the secondary windings of the transformers for an open.
If in diagnosing a malfunction, it is necessary to disable the inverter protection, there is a risk of failure of the power elements of the inverter, and special care is required during work, and after they are finished, it is necessary to restore the protection circuits for further safe operation of the TV by the owner in normal mode.
- The TV does not enter the operating mode, does not respond to the remote control. The indicator on the front panel lights constantly or blinks.
Repair or diagnostics of the JV-508F-A02 motherboard should begin by checking the stabilizers and power converters needed to power the chips and matrix. If necessary, update or replace the software (software).
Main features of the ELENBERG TV-1007 device:Attention TV owners! Self-repair attempts by ELENBERG TV-1007 are not recommended by the manufacturer and can lead to serious negative consequences!
Installed matrix (LCD panel) LQ104V1DG83.
The required supply voltage for all nodes of the TV ELENBERG TV-1007 provides a switching power supply.
MainBoard - the main board (motherboard) is a JV-508F-A02 module.
Additional technical information about the panel:
Brand: SHARP
Model: LQ104V1DG83
Type: a-Si TFT-LCD, Panel
Diagonal size: 10.4 inch
Resolution: 640x480, VGA
Display Mode: TN, Normally White, Transmissive
Active Area: 211.2x158.4 mm
Surface: Antiglare, Hard coating (3H)
Brightness: 350 cd / m²
Contrast Ratio: 300: 1
Display Colors: 262K (6-bit), CIE1931 72%
Response Time: 10/25 (Tr / Td)
Frequency: 60Hz
Lamp Type: 2 pcs CCFL Embedded (Inverter)
Signal Interface: Parallel RGB (1 ch, 6-bit), 32 pins
Voltage: 3.3 / 5.0V (VCC)