LOEWE Xelos L 2650 P 2650 SERVICE MODE Option Byte Table.
TO ENTER SERVICE MODE
- Press 'Function button M' on the remote control once.
- Press 'Right Arrow' button (inner ring) of the remote control repeatedly "until indication (Service) will be marked and within a second, press "Menu" button on the remote control. {Locate all the above said buttons on the remote control, prior to enter the service mode procedure and fast action is necessary.}
OPTION BYTE TABLE.
Alignment function.
|
Bit No
|
Meaning
|
“0”
|
“1”
|
Adjusted in the Factory
|
Byte 0
|
1
|
EPG program filter.
|
On
|
Off
|
0
|
5
|
Blue picture without signal.
|
Yes
|
No
|
0
|
|
Byte 1
|
1
|
Effect light for background.
|
Off
|
On
|
0
|
2
|
WSS detection in VCR mode
|
No
|
Yes
|
1
|
|
3
|
AMD [Atom. Movie detection]
|
On
|
Off
|
0
|
|
7
|
At VGA mode sync failure.
|
Change to TV mode
|
Keep VGA mode
|
1
|
|
Byte 2
|
6
|
Reaction time of remote commands.
|
Fast
|
Slow
|
0
|
7
|
WSS [Wide Screen Signaling Bits]
|
Evaluated
|
Not evaluated
|
0
|
|
Byte 3
|
0
|
Picture ratio.
|
Evaluated
|
Blocked
|
0
|
2
|
Analogue EPG night update.
|
Off
|
On
|
1
|
|
4
|
Switching off after channel closes.
|
Yes
|
No
|
0
|
|
5
|
Factory mode
|
Off
|
On
|
0
|
|
Byte 4
|
2
|
Power down cycle.
|
Yes
|
No
|
0
|
4
|
SMD switch over.
|
Fast
|
Slow
|
1
|
|
5
|
Warm up mode
|
On
|
Off
|
1
|
|
Byte 5
|
2
|
PIP within EPG
|
Last program
|
Selected program ‘now’
|
0
|
3
|
Sound AURO
|
SPDIF – out TV
|
Analogue sound from SCART 2
|
0
|
|
Byte 6
|
6
|
Indication of movie mode
|
No
|
Yes (with color of Side Panels)
|
0
|
7
|
VT sub pages mode
|
Normal
|
Off
|
0
|
|
Byte 7
|
4
|
Accessing the 16:9 switching voltage
|
Yes
|
No
|
0
|
Byte 8
|
0
|
Factory mode
|
No
|
Yes
|
0
|
7
|
Auto on [warm up]
|
Off
|
On
|
0
|
|
Byte 9
|
0
|
Chroma output at SCAT-1
|
Pin 7
|
Pin 15
|
0
|
1
|
Ext. receiver in VT mode
|
Autom. Channel recognition
|
No autom. recognition
|
0
|
|
4
|
DISqC telegramm
|
Also for not used switch.
|
Only for not used switch
|
0
|
|
7
|
Rotation control
|
No
|
Yes
|
1
|
|
Byte 10
|
0
|
Signal peaks
|
Yes
|
No
|
0
|
1
|
Program change in overview
|
Possible
|
Not possible
|
0
|
|
4
|
Correction of MSP registers.
|
No
|
Yes [sound problem Luxembourg]
|
0
|