REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Thursday, 24 September 2020

KALLEY K-LEDHDST2 LED TV – ENTER SERVICE MODE, FACTORY MODE, SOFTWARE UPDATE PROCEDURE , POWER AND AMPLIFIER SCHEMATIC DIAGRAMS

K-LED32HDST2/MS08GP-LA/Smart TV/CSFGTA

Alignment Procedure-MS08GP Series-L32D2700/L40D2700

MS08GP These chassis are designed for Eastern Europe markets Ready for IPTV. The main chip is from Mstar and supports below features matrix:
Factory Menu:  Methods of Entering
Method 1: Using the remote control
Select “Picture” and press “OK” key to enter into Picture Mode press RIGHT” or “LEFT” key Select User Mode
Press the subsequence RCU keys “
9”, “7”, “3 and 5 will appear in the left top of screen In case of “Factory hotKey” is enabled On , just press RCU “Return” key to pop-up again the Factory menu.
The status of “Factory Key” can be changed in Factory Menu->Hotkey.
Press RCU “OK” key or “RIGHT” key to enter the submenu.
Press RCU “Menu” key to go back to the root menu.
Press RCU “RIGHT” or “LEFT” key to change the values.
Press RCU “OK” key run the function.
Press RCU “Exit” key exit the Factory menu.

Design Menu

Methods of Entering
Method 1: Using the remote, enter the “Picture” submenu in the OSD; choosing the “contrast” item and press the 1,9,5,and 0 in series ,Design Menu will appear in the left top of screen.
Method 2: Press RETURN button when DESIGN HOTKEY is enabled (ON).

Hotel menu

Service Menu
1.Methods of Entering
Using the remote, enter the “Picture” submenu in the OSD; choosing the “contrast” item and press the 9,7,0 and 5 in series, Service Menu will appear in the left top of screen.

Debugging
5.1. General Steps of debugging
According to the requirement of the order, below steps are needed for appropriate setting.
1) Enter the Factory Menu, enable FAC HOTKEY.
2) Check Project ID and the version of software, release date displayed at the bottom of Factory Menu.
3) Enter Design Menu, choose SERVICE MENU
èProject ID, choose corresponding Project ID number of the product (Refer to the “V6-PROJECT -ID0**”in the BOM list).
4) Return to Factory Menu, check the Product model.
5) Choose Factory Menu->NVM RESET and press the right button of the remote and wait until prompt OK appears.
6) Restart the set
7) According to the requirement of the order, Set the items of SHOP INIT and Hotel Menu etc.

8) After aging under normal temperature, calibrate ADC and adjust white balance.

9) Choose Factory Menu ->SHOP and press the button of remote to initialize the set.
Note: After step 9, Hotel Menu will be disabled by default. Therefore, if the order requires hotel function, it is necessary to enable hotel function by set Design MENU->Service Menu->HOTEL ENABLE to ON.
Equipment
·Color Analyzer CA-210.
·Video Pattern Generator Chroma2329.
·Color TV Pattern Generator PM5418/Fluke5418.
·VGA cable , AV(RCA) cable , HDMI cable etc.




5.3. ADC Function

not Calibration

 

5.4. White Balance adjustments (Manual)


 

Before adjustment ,you must make sure the ADC status(only PC and YPbPr)


 

is

“success”and

Color

Analyzer

has

been

calibrated

.Only

AV1,YPbPr,PC,HDMI1 need to be adjusted. HDMI1 should be the first.
Signal and generator
The pattern of the signal should be used are White (Chroma2329 pattern 113) and Grey (pattern 114).
The format of signal are respectively 720P for HDMI1 (Chroma2329 Timing 69),PAL (Chroma2329 Timing38) for AV1,1024X768@60Hz(Chroma2329 Timing14) for VGA

Steps of adjustment
1).Enter the factory menu-> White Balance, select source HDMI 1 and Normal Temperature.
2).Input grey signal in 720p format.
3).Change R-OFFSET and B-OFFSET to make sure the value of color coordination equal to (X=0.270 +/-0.015;Y=0.290 +/-0.015).
4).Input white signal in 720p format.
5).Change R-GAIN and B-GAIN to make sure the value of color coordination equal to (X=0.270 +/-0.015;Y=0.290 +/-0.015).

6).Repeat step 2—5 until both of the value of color coordination of white and grey equal to (X=0.270 +/-0.015;Y=0.290 +/-0.015).
For COOL and WARM color temperature, just repeat step 2—5.The color coordination we recommend for COOL and WARM color temperature is respectively(X=0.270 +/-0.015;Y=0.270 +/-0.015) and (X=0.300 +/-0.015;Y=0.305 +/-0.015).
After the adjustment of HDMI1, you can switch to other source AV, PC and YPbPr and repeat step 1—6 to do the WB adjustment.
Note: For some small size LED panel,the color coordination of specifications is not X=0.270/Y=0.290,and we recommend you adopt the values from panel specifications.
 ADC Calibration and White Balance Adjustment (automatic)
The process of adjusting White Balance automatically is out of the range of this file, Please refer to the relevant technical file of HuiZhou factory of TCL.
6.Chip list of software programming before SMT
Following chips must be programmed before SMT by tools

Position

Chip type

Software description

U301

MT29F2G08ABAEA

HDMI HDCP Key, System Software etc.

Software update: Method of SW update:
1.Download the bin file to the root directory of your USB device (Do not change the file name); Then insert the USB device to USB interface of TV set.
MS08GPSeries with its upgrade file corresponding relation as the table below show:

Chassis Name

Sales
area

Upgrade filename

Remark

MS08GP

LA

MS08GP_MAIN.bin

DVB-T2

How to upgrade FLASH SW using USB

Copy the SW BIN image MS08GP_MBOOT.bin” into USB stick root path.
Note: If there’s already other “MS08GP_MBOOT.bin” into USB root, it needs to be deleted or renamed.

Plug USB stick to the TV USB slot.
Press RCU MENU
èOptionèSoftware upgradeèBy USBèConfirm.
Or, turn off the TV press and hold the power key of key board before reconnect AC cord to restart TV for 5-8seconds (Forced Upgrade).
When the "UPGRADING SOFTWARE" picture appears as below, it means TV is uploading SW BIN image. Waiting a few minutes.

When updating is successful, TV should restart automatically.
There are two methods to upgrade SW using USB, the first one like below
In the previous of upgrade SW using USB, should program mboot bin file
MS08GP_MBOOT.binby ISP_Tool or by USB. .
Then switch off TV by removing AC cord.
Copy the SW BIN image
MS08GP_MAIN.bin” for MS08GP into USB stick (pen
drive) root path
Note: If there’s already other The same name into USB root, it needs to be deleted or renamed
Plug USB stick to the TV
Press and hold the power key of key board before reconnect AC cord to restart TV for 5-8seconds.
Once USB stick starts blinking, TV is uploading SW BIN image.
When update is successful, TV should restart automatically.
Remember to perform “Factory menuÆNVM reset“ and then press RCU “OK” key
Switch off TV by removing AC cord
Reconnect AC cord to restart TV and wait few seconds for Eeprom update.

The second method
To use this method, there should be SW in mainboard to ensure TV can display normally.
Copy the SW BIN image
MS08GP_MAIN.binand into USB stick (pen drive) root path
Press RCU MENU
èOptionèSoftware upgradeèBy USèConfirm
TV display warning information, that means it is upgrading, almost 3minutes later, when upgrade successful, TV should restart automatically.

How to change Project ID with Remote Control Unit (RCU)

Process following subsequence IR codes to change project ID:
062598+MENU+xxx (xxx: Project ID, ex: 001)
Restart TV

How to upgrade MAC Address

Upgrading MAC address need to use the tool in factory and through serial command, the specific methods according to the operation of the factory guidance.

Instructions of Updating SW”
1. The following IC should be pre-copied before SMT process

Position

PART TYPE

Part Number

SW

U301
CPP

IC-TSOP48

13-FS29F2-G0B

Mboot, Main Software

2.The MAC Address, HDCP KEY, Device ID must be upgrade by debug port into U301.

Project ID selecting
1)Press the Menu button of remote control, then select Contrast item of Picture submenu; press 1,9,5,0 consecutively, there you go the Design Menu.
2) Select the SERVICE MENU item, press OK and RIGHT button of the remote to enter submenu,
3)Select the PROJECT ID item, press OK or RIGHT button of the remote to enter the submenu;
4)Press the right or left button of the remote to select the ID you want;
5)After ID selection, press MENU button of the remote to exit DESIGN MENU.
6)Finally, do AC power on/off.